NEW UC INSTRUMENTS GM82009L SALES and UC INSTRUMENTS GM82009L CALIBRATION

 
Custom-Cal has for sale a new UC INSTRUMENTS GM82009L. Also, short calibration turn times minimize downtime and reasonable rates decrease your long-term cost of ownership and minimizes downtime of the UC INSTRUMENTS GM82009L. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Tunable Laser Source (TLS)?
Shop for Comparable Products on our
 used Tunable Laser Source (TLS) page or new Tunable Laser Source (TLS) page

 
List Price for a new UC INSTRUMENTS GM82009L, $7,200.00   UC INSTRUMENTS GM82009L   Description / Specification:   Spec Sheet 
UC INSTRUMENTS GM82009L L-Band Tunable Laser Module (PC)

The UC INSTRUMENTS GM82009L Tunable Laser Module offers superior performance for the test of DWDM components, AWG & PLC components, optical amplifiers, and other general purpose of fiber optical test and measurement applications. Especially for fiber grating sensor fast sweep testing. The tunable laser module is connected to a PC with RS232 cable. Specifications. Wavelength range: 1566.00 to 1610.00 nm. Output Power: >= 10 dBm. Wavelength resolution: 1.0 pm. Absolute wavelength accuracy: +/- 10 pm, tpy. < 5 pm. Relative wavelength accuracy: +/- 5 pm, Typ. +/- 2 pm. Wavelength repeatability: +/- 2 pm, typ. +/- 1 pm. Wavelength stability (typ., 24 hrs at constant temperature: <= +/- 2 pm. Tuning speed: <= 2 ms per step. Power stability: +/- 0.05 dB, 1 hour. Typ., +/- 0.1 dB, 24 hours. Power repeatability: +/- 0.05 dB. Power linearity: +/- 0.3 dB. Power flatness versus wavelength: 0.3 dB typ., 0.5 dB max.. Side-mode Suppression ratio: >= 45 dBc. Relative intensity noise (RIN. Typ.): < -135 dB. Output optical interface: PM, FC/PC connector. Interface: RS232. Output trig port: BNC trig. Dimensions: 35 mm H, 130 mm W, 170 mm D. Weight 0.5 kg.



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the UC INSTRUMENTS GM82009L. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chromatic Dispersion
Chromatic Dispersion is a broadening of the input signal as it travels down the length of the fiber. Chromatic Dispersion results from a variation in propagation delay with wavelength, and is affected by fiber materials and dimensions.

Detector
A Detector is a signal conversion device that converts power from one form to another, such as from optical power to electrical power

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Polarization Mode Dispersion (PMD)
Polarization mode dispersion (PMD) is a form of modal dispersion where two different polarizations of light in a waveguide, which normally travel at the same speed, travel at different speeds due to random imperfections and asymmetries, causing random spreading of optical pulses. It is he difference between the maximum and minimum values of loss typically measured in ps/km^1/2.


Please contact us for your new UC INSTRUMENTS GM82009L sale price and/or UC INSTRUMENTS GM82009L CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: